• HOME
  • PRODUCTS
    • Gyrolok Tube Fittings
    • Instrumentation Valves
      • Ball Valve
      • Needle Valve
      • Flow and Fluid Control Components
      • Packless Valves
      • Metering Valves
      • Plug Valves
      • Manifolds
      • Guage Valves
      • Hand Valves
      • Doubles Block & Bleed Valves
      • HOKE Block Valves
      • HOKE Monoweld Valves
    • Actuators
      • Space Saver Actuators
      • Electric Actuators
      • Pneumatic Actuators
    • Flow & Fluid Control Components
    • Pipe Fittings
    • Instrumentation Manifolds
    • HQC Series Quick Couplings
    • Sampling Cylinders
      • Spun Sampling Cylinders
      • Formed Sampling Cylinders
      • Sampling Cylinder Valves and Accessories
    • Tools and Miscellaneous
  • APPLICATIONS
    • Alternative Fuels Market
    • Chemicals and Petrochemicals Market
    • OEM Applications
    • Oil and Gas Markets
    • Power Generation Markets
    • Pulp and Paper Markets
  • RESOURCES
    • Certificates
    • Export Compliance
    • Literature
    • Request Info
    • Supplier References
  • ABOUT US
  • DISTRIBUTORS
  • CONTACT US

Call us ! 864.574.7966

Request Info
Distributors Login
Hoke Hoke
  • HOME
  • PRODUCTS
    • Gyrolok Tube Fittings
    • Instrumentation Valves
      • Ball Valve
      • Needle Valve
      • Flow and Fluid Control Components
      • Packless Valves
      • Metering Valves
      • Plug Valves
      • Manifolds
      • Guage Valves
      • Hand Valves
      • Doubles Block & Bleed Valves
      • HOKE Block Valves
      • HOKE Monoweld Valves
    • Actuators
      • Space Saver Actuators
      • Electric Actuators
      • Pneumatic Actuators
    • Flow & Fluid Control Components
    • Pipe Fittings
    • Instrumentation Manifolds
    • HQC Series Quick Couplings
    • Sampling Cylinders
      • Spun Sampling Cylinders
      • Formed Sampling Cylinders
      • Sampling Cylinder Valves and Accessories
    • Tools and Miscellaneous
  • APPLICATIONS
    • Alternative Fuels Market
    • Chemicals and Petrochemicals Market
    • OEM Applications
    • Oil and Gas Markets
    • Power Generation Markets
    • Pulp and Paper Markets
  • RESOURCES
    • Certificates
    • Export Compliance
    • Literature
    • Request Info
    • Supplier References
  • ABOUT US
  • DISTRIBUTORS
  • CONTACT US
Catalog
CAD (0) ▾
  • Cart is empty
  1. Request CAD files
  • Sign In
CAD Products > Valves > Manifolds > HM Series - Manifolds

HM Series - Manifolds


Request Information Search by Specification
HM Series - Manifolds hm-series---manifolds
Remote Mount 2-Valves Manifold Model-HM8232

Remote Mount 2-Valves Manifolds, Model-HM8232

(308) Using the 2-valve manifold
In normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Remote-Mount-2-Valves-Manifold-Model-HM8232.JPG
Direct Mount 2-Valves Manifold Model-HM8212

Direct Mount 2-Valves Manifolds, Model-HM8212

(308) Using the 2-valve manifold
In normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Direct-Mount-2-Valves-Manifold-Model-HM8212.JPG
Remote Mount 2-Valves Manifold (Flat Face) Model-HM8262

Remote Mount 2-Valves Manifolds (Flat Face), Model-HM8262

(308) Using the 2-valve manifold
In normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Remote-Mount-2-Valves-Manifold--Flat-Face--Model-HM8262.JPG
Direct Mount 2-Valves Manifold (Enclosure) Model-HM8292

Direct Mount 2-Valves Manifolds (Enclosure), Model-HM8292

(308) Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-2-Valves-Manifold--Enclosure--Model-HM8292.JPG
Remote Mount 2-Valves Manifold Model-HM82GAM8

Remote Mount 2-Valves Manifolds (With 1/2" Intregral GA Adapter), Model-HM82GAM8

(308) Using the 2-valve manifold
In normal operation the “isolate” valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Remote-Mount-2-Valves-Manifold-Model-HM82GAM8.JPG
Remote Mount 3-Valves Manifold Model-HM8332

Remote Mount 3-Valves Manifolds, Model-HM8332

(308) Using the 3-valve manifold
In normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Remote-Mount-3-Valves-Manifold-Model-HM8332.JPG
Direct Mount 3-Valves Manifold Model-HM8312

Direct Mount 3-Valves Manifolds, Model-HM8312

(308) Using the 3-valve manifold
In normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Direct-Mount-3-Valves-Manifold-Model-HM8312.JPG
Remote Mount 5-Valves Manifold Model-HM8532

Remote Mount 5-Valves Manifolds, Model-HM8532

(308) Using the 5-valve manifold
In normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Remote-Mount-5-Valves-Manifold-Model-HM8532.JPG
Direct Mount 5-Valves Manifold Model-HM8512

Direct Mount 5-Valves Manifolds, Model-HM8512

(308) Using the 5-valve manifold
In normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Direct-Mount-5-Valves-Manifold-Model-HM8512.JPG
Direct Mount 5-Valves Manifold (Enclosure) Model-HM8592

Direct Mount 5-Valves Manifolds (Enclosure), Model-HM8592

(308) Using the 5-valve manifold
In normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
/Asset/Direct-Mount-5-Valves-Manifold--Enclosure--Model-HM8592.JPG
Mounting Bracket Kits

Mounting Bracket Kits

(4) Mounting bracket kits enable a user to mount a manifold onto a gauge stand or a 2in (50mm) nominal bore pipe stand. Mounting kits are manufactured in stainless steel and allow the instrument to be removed without disturbing the impulse pipework connection.

They also add support to the complete assembly.
/Asset/Mounting-Bracket-Kits.JPG
*

© 2020 — Crane Co.

  • Privacy Policy
  • Terms & Conditions