CAD (0)
▾
Using the 3-valve manifold
In normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
In normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
Unit of Measure
Specifications
Tip |
N/A Soft |
Packing |
N/A GRAFOIL |
Inlet Connection |
N/A Integral GYROLOK |
Inlet Size |
N/A 10 mm |
Alloy |
N/A 825 INCONEL® |
Weight |
N/A 3.08 lb1.4 kg |
Maximum pressure at 212 ºF (100 ºC) |
N/A 6000 psi413 bar |
Maximum pressure at 842 ºF (450 ºC) |
N/A 3300 psi230 bar |
Pressure Equipment Directive
N/A Due to internal bore size and internal volumes up to and including 1"/25mm, products offered in this catalogue comply with S.E.P (Sound Engineering Practice) article 3, paragraph 3 of the Pressure Equipment Directive P.E.D. 97/23/EC and therefore CE marking is not applicable. |