Print Back
Used strictly for pre-assembling ferrules to tubing.
Threads of pre-setting tools should be lubricated the very first time and relubricated every tenth time thereafter.
Unit of Measure

Specifications

T - Tube O.D.

N/A 10 mm

L

N/A 50.8 mm

Across Flats

N/A 17.3 mm

Usage Instructions

N/A
1. Place PST in vise.
2. Loosely assemble nut and ferrules to PSI. Use HOKE Gyrolok Safety Changer Nut & Ferrule Sets.
3. Follow standard HOKE Gyrolok assembly instructions to set ferrules onto tubing, see page 53.
4. Loosen nut and remove tubing with pre-set ferrules and nut.
5. With pre-set ferrules and nut in permanent location, reassemble tubing by HOKE Gyrolok reassembly instructions.