HM Series - Manifolds
hm-series---manifolds
In normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-2-Valves-Manifold-Model-HM8232.JPG
In normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-2-Valves-Manifold-Model-HM8212.JPG
In normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-2-Valves-Manifold--Flat-Face--Model-HM8262.JPG
In normal operation the “isolate” valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-2-Valves-Manifold-Model-HM82GAM8.JPG
In normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-3-Valves-Manifold-Model-HM8332.JPG
In normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-3-Valves-Manifold-Model-HM8312.JPG
In normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-5-Valves-Manifold-Model-HM8532.JPG
In normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-5-Valves-Manifold-Model-HM8512.JPG
In normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-5-Valves-Manifold--Enclosure--Model-HM8592.JPG
They also add support to the complete assembly. /Asset/Mounting-Bracket-Kits.JPG
Remote Mount 2-Valves Manifolds, Model-HM8232
(308) Using the 2-valve manifoldIn normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-2-Valves-Manifold-Model-HM8232.JPG
Direct Mount 2-Valves Manifolds, Model-HM8212
(308) Using the 2-valve manifoldIn normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-2-Valves-Manifold-Model-HM8212.JPG
Remote Mount 2-Valves Manifolds (Flat Face), Model-HM8262
(308) Using the 2-valve manifoldIn normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-2-Valves-Manifold--Flat-Face--Model-HM8262.JPG
Direct Mount 2-Valves Manifolds (Enclosure), Model-HM8292
(308) Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-2-Valves-Manifold--Enclosure--Model-HM8292.JPGRemote Mount 2-Valves Manifolds (With 1/2" Intregral GA Adapter), Model-HM82GAM8
(308) Using the 2-valve manifoldIn normal operation the “isolate” valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-2-Valves-Manifold-Model-HM82GAM8.JPG
Remote Mount 3-Valves Manifolds, Model-HM8332
(308) Using the 3-valve manifoldIn normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-3-Valves-Manifold-Model-HM8332.JPG
Direct Mount 3-Valves Manifolds, Model-HM8312
(308) Using the 3-valve manifoldIn normal operation the "isolate" valves are open while the "equalize" valve is closed.
This provides a differential pressure reading to the pressure gauge or transmitter. To zero the instrument, first close the downstream "isolate" valve then open the "equalize" valve and adjust the zero setting on the instrument.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-3-Valves-Manifold-Model-HM8312.JPG
Remote Mount 5-Valves Manifolds, Model-HM8532
(308) Using the 5-valve manifoldIn normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Remote-Mount-5-Valves-Manifold-Model-HM8532.JPG
Direct Mount 5-Valves Manifolds, Model-HM8512
(308) Using the 5-valve manifoldIn normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-5-Valves-Manifold-Model-HM8512.JPG
Direct Mount 5-Valves Manifolds (Enclosure), Model-HM8592
(308) Using the 5-valve manifoldIn normal operation the “isolate” valves are open while the "equalize" and "vent" valves are closed. This provides a differential pressure reading to the pressure gauge or transmitter.
To zero the instrument, first close both “vent” valves and the downstream "isolate" valve. Then open the "equalize" valve and adjust the zero setting on the instrument.
To remove the instrument, first close both "isolate" valves, then open the "equalize" valves to relieve pressure between the manifold and the instrumet.
Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard. /Asset/Direct-Mount-5-Valves-Manifold--Enclosure--Model-HM8592.JPG
Mounting Bracket Kits
(4) Mounting bracket kits enable a user to mount a manifold onto a gauge stand or a 2in (50mm) nominal bore pipe stand. Mounting kits are manufactured in stainless steel and allow the instrument to be removed without disturbing the impulse pipework connection.They also add support to the complete assembly. /Asset/Mounting-Bracket-Kits.JPG