CAD (0)
▾
This panel mountable, two-piece design is available in globe and angle patterns for fl exibility of installation.
Dyna-Pak packing provides leak-tight sealing with low operating torque. Optional Graph-Lock packing is
available for high-temperature applications. The safety back-seating prevents accidental removal of the stem.
Typical Applications Hydraulic systems
High temperature service to +600° F (+316° C)
Gas sampling
Test stands
Typical Applications
Unit of Measure
INLET A |
N/A 1/2" female NPT |
OUTLET B |
N/A 1/2" female NPT |
D |
N/A 3 3/4 in95 mm |
E |
N/A 2 1/2 in64 mm |
F |
N/A 2 3/8 in60 mm |
H |
N/A 5/8 in16.0 mm |
H1 |
N/A 15/16 in24 mm |
Flow Pattern |
N/A Globe |
Stem Tip |
N/A Metal stem tip; Graph-Lock high temperature packing for service to +600° F (+316° C) |
Body Material |
N/A Carbon Steel |
Maximum Operating Pressure |
N/A 5000 psig at 70° F (345 bar at 21° C) |
Operating Temperature Range |
N/A -60° to 600° F (-51° to 316° C) |
Orifice |
N/A 0.313 in8.00 mm |
Cv Factor |
N/A 1.20 |
Panel Hole |
N/A 19.4 mm49/64 in |
Panel Thickness |
N/A 4.7 mm3/16 in |
Features & Benefits |
N/A
Safety High pressure capability Extended temperature range Versatile Reliability Panel mounting |