Print Back
Using the 2-valve manifold
In normal operation the "isolate" valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
Remote Mount 2-Valves Manifold Model-HM8232
Remote Mount 2-Valves Manifold Model-HM8232-2
Unit of Measure
Items Remote Mount 2-Valves Manifold Model-HM8232
HM823211F8YL
Remote Mount 2-Valves Manifolds, Model-HM8232
Remote Mount 2-Valves Manifold Model-HM8232
HM823211F8HC
Remote Mount 2-Valves Manifolds, Model-HM8232
Remote Mount 2-Valves Manifold Model-HM8232
HM823211F8M
Remote Mount 2-Valves Manifolds, Model-HM8232
Remote Mount 2-Valves Manifold Model-HM8232
HM823211F8D50
Remote Mount 2-Valves Manifolds, Model-HM8232
Remote Mount 2-Valves Manifold Model-HM8232
HM823211F8TI
Remote Mount 2-Valves Manifolds, Model-HM8232
Tip N/A Hard
Packing N/A PTFE
Inlet Connection N/A Female
Inlet Size N/A 1/2" NPT
Alloy N/A 316/316L N/A HASTELLOY® C276 N/A MONEL® N/A Super Duplex N/A Titanium
Weight N/A 1.98 lb0.9 kg
Maximum pressure at 212 ºF (100 ºC) N/A 6000 psi413 bar
Maximum pressure at 392 ºF (200 ºC) N/A 4000 psi275 bar
Maximum pressure at 842 ºF (450 ºC) N/A