Print Back
connects two metric ports
Unit of Measure

Specifications

Material

N/A 254 SMO

T - Tube O.D.

N/A 12 mm ReducingPortConnectorPCMMDimDraw.jpg

Tx - Tube O.D.

N/A 6 mm

A

N/A 39.0 mm

C

N/A 17.5 mm

E Min

N/A 4.4 mm

L

N/A 21.2 mm

Installation Instruction

N/A For Port Connector and Reducing Port Connector:
1. Firmly insert machined ferrule end into fitting body.
2. Place nut only (no ferrules) over the machined ferrule. Finger-tighten.
3. Using wrench, turn nut until sharp rise in torque is felt. Snug tight. (Do not tighten 1 1/4 turns. No ferrules to set.)
4. Insert tube stub end into HOKE Gyrolok assembly.