Print Back
Using the 2-valve manifold
In normal operation the “isolate” valve is open while the "vent" valve is closed.
To remove the instrument, first close the "isolate" valve, then open the "vent" valve to relieve pressure upstream of the "isolate" valve.

Note: The body & trim parts on all 316/316L Valves & Manifolds comply to NACE MR-01-75 & NORSOK M-650 as standard.
Unit of Measure

Specifications

Type

N/A Remote

Fixed

N/A 2

Tip

N/A Soft

Packing

N/A GRAFOIL

Inlet Connection

N/A Integral GYROLOK

Inlet Size

N/A 1/2"

Alloy

N/A 6%Mo

Weight

N/A 3.3 lb1.5 kg

Maximum pressure at 212 ºF (100 ºC)

N/A 6000 psi413 bar

Maximum pressure at 842 ºF (450 ºC)

N/A 3300 psi230 bar

Calibration Option

N/A By connecting a calibration gauge to the vent port, it is possible to check the calibration of the instrument without removing it from the installation.

Pressure Equipment Directive

N/A Due to internal bore size and internal volumes up to and including 1"/25mm, products offered in this catalogue comply with S.E.P (Sound Engineering Practice) article 3, paragraph 3 of the Pressure Equipment Directive P.E.D. 97/23/EC and therefore CE marking is not applicable.